Operating Instructions
Even when the on time may have been manually reduced from within this screen to a safe
level (usually less than 10) the transmitter will not automatically restart. Select this option to
restart the transmitter.
A restored drive will display a drive current that is greater than the safe mode value. If this is
the case it is recommended to start the auto configure process rather than attempt a manual
on time adjustment. If the drive does not restore then the transmitter may be in shutdown.
Remove the control box front panel then drop down the internal hinged main control board to
allow visual access to the left hand transmitter board. If the bottom red LED is illuminated then
the transmitter is in shutdown. If only the orange led is illuminated then the transmitter is still
in safe mode. In this case, try lowering the on time value a little more and perform another
restore drive.
If the red LED stays on then contact your local Loma service centre for assistance.
Auto Configure
Select this option to start the full setup process for all operating frequencies. The process
commences by resetting the on time values for each frequency to zero.
The configuration progress is displayed and will close automatically upon completion.
Configure current
This entry sets the target transmitter drive current that the auto configure process will use,
subject to a maximum figure of 350mA.
For conveyor detectors using the standard board, the default value is 230mA. For conveyor
detectors using the auto-balance board, the default value is 350mA.
Setting Up the User Options
To set up the User Options, proceed as follows:
1.
Select Menus > Set Up > User Options to display the available menu options which are
listed and described below.
2.
Use the Navigation Keys
to select each option in turn press the OK /
Enter Key
to enable the value to be edited.
3.
Use the Navigation Keys
to select the required option value and then
press the OK / Enter Key
to confirm the selection.
4. Repeat step 2 and 3 until you have selected and confirmed values for each option.
The User options available for selection are as follows:
Menu Scroll
If this option is enabled then selecting either the Up or Down Navigation Keys will display the
available options in a continuous loop. In effect you only need to keep pressing the one
Navigation Key button to view all available options.
Bar Graph
Options are provided to change the display so that the product signal is shown as a bar graph
rather than a number or a combination of the two displayed at the same time.
85